Dynamix DW 4 FXO Podręcznik Użytkownika Strona 74

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 84
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 73
74
Figure 13.
b. Line #2 of FXO Gateway setting, see Figure 14.
An FXS port 2 incoming call routes to FXO port 2 configuration example.
Incoming Call Type : VOIP
Matched Prefix : 1002
Matched Length : 0
No Answer Timeout : 30 (MUST be longer than 10 seconds).
Outgoing Type : FXO
Hunting Type : selected anyone.
Routing List : 01. Line 2 ; 02. None. ; 03. None ; 04. None.
Figure 14.
c. Line #3 of FXO Gateway setting, see Figure 15.
An FXS port 3 incoming call routes to FXO port 3 configuration example.
Incoming Call Type : VOIP
Matched Prefix : 1003
Matched Length : 0
No Answer Timeout : 30 (MUST be longer than 10 seconds).
Outgoing Type : FXO
Hunting Type : selected anyone.
Routing List : 01. Line 3 ; 02. None. ; 03. None ; 04. None.
Przeglądanie stron 73
1 2 ... 69 70 71 72 73 74 75 76 77 78 79 ... 83 84

Komentarze do niniejszej Instrukcji

Brak uwag