Dynamix DW 2 FXO Instrukcja Użytkownika Strona 79

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 85
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 78
Dynamix DW-2/4 FXO SIP Gateway User Manual
9. There are three values you will get after analyzing. Please leave the value
which is over 1000 Hz, this is not the frequency of disconnect tone.
10. Please put the frequency in the tone table just follow the command
tone 4 420 680 8 8 25 25 50 50
Example-1
(Make a call from PSTN to FXO port)
usr/config$ record -tone
Press (R) to start record...
(Please make sure that you are already finish the steps 2 ~ 7)
r (Press “Enter” button after you key in “R”)
Analizing!! Please wait a moment...
(You coule hang up the call from PSTN if you get this message)
Frequency 1 : 481
Frequency 2 (2623) is more than 1000, please ignore it.
Frequency 3 : 621
tone 4 481 621 8 8 25 25 1023 1023
(Put this value in to the tone table)
tone –print
Disconnect tone 1 paramter
Frequency high : 620
frequency low : 480
frequency high level : 8
frequency low level : 8
Tone1 on : 25
78
Przeglądanie stron 78
1 2 ... 74 75 76 77 78 79 80 81 82 83 84 85

Komentarze do niniejszej Instrukcji

Brak uwag