Dynamix UM-SE G.SHDSL.bis EFM Bridge Modem User Manual V003 46
3.6 Status
When you click STATUS You can monitor the following : SHDSL.bis EFM, MGMT, LAN and
INTERFACE
3.6.1 SHDSL .Bis EFM
SHDSL.bis status including run-time device status : mode and Bitrate and Performance
information: SNR margin, atteunation and CRC error count.
4-pairs model (8 wire model)will showed as following, you can know about their four channel
run-time status( from channel A to D).